myFreelander.co.uk

Freelander - Air Conditioning

NOTE - current data only applies to MY01 >

System CFC free, sealed, closed-loop system
Refrigerant HFC - R134a
Refrigerant charge quantity:
  • All models except LHD KV6
  • LHD KV6 models
 
  • 540 ± 25 grammes
  • 430 ± 25 grammes
Compressor:
  • Type
  • Pressure (high side)
  • Pressure (low side)
  • Displacement (min.)
  • Displacement (max.)
 
  • Denso - variable displacement, 7-cylinder swash plate unit
  • 35.3 bar (3.53 MPa, 512 lbf/inČ)
  • 16.7 bar (1.67 MPa, 242 lbf/inČ)
  • 5%
  • 95%
Lubricating oil Nippon Denso ND-8
Evaporator Thermostat:
  • Opens
  • Closes
 
  • +2° C (+36° F)
  • -4° C (+25° F)
Condenser fan control PWM signal from ECM to cooling fan control unit
Refrigerant Pressure sensor  
Low pressure limit:
  • A/C on (pressure rising)
  • A/C off (pressure falling)
 
  • 2.25 ± 0.2 bar (32.6 ± 2.9 lbf/inČ)
  • 1.96 ± 0.2 bar (28.4 ± 2.9 lbf/inČ)
High pressure limit:
  • A/C off (pressure rising)
  • A/C on (pressure falling)
 
  • 31.4 ± 0.2 bar (455.3 ± 29 lbf/inČ)
  • 25.5 ± 0.2 bar (369.8 ± 29 lbf/inČ)
myFreelander Search